Precor EFX546 Manuel de service Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
C546 Elliptical Fitness Crosstrainer
Page 8
Procedure 3.2 - Accessing the Diagnostic Program (version
1)
The EFX diagnostic software cycles through the following tests:
LED Diagnostics
Power Bits
Lift Calibration Number
Heart Rate
Keypad Test
Procedure
1. Plug the power cord into the wall outlet, then turn on the EFX with the circuit breaker.
2. Press keys RESET,5,1,7,6,5,7,6,1., sequentially.
3. Watch the upper display as the LED test progresses. The test will illuminate every LED on
the display. The test will illuminate the LED’s in a specific pattern. When you are familiar
with the pattern, it is easy to determine when a LED does not illuminate.
4. If you do not observe the LED illumination sequences described in Step 3...
THEN... OTHERWISE...
Replace the upper PCA as described The LED test passed successfully;
in Procedure 7.2 or 7.3. continue with the next step.
5. Power Bits will be displayed. Power bits indicates the amount of power being applied to the
eddy current magnets and will vary directly with the resistance. Press ENTER to continue.
6. With LIFT displayed in the right display window, watch the right display window (shown in
Diagram 3.1). Press the CROSSRAMP
or CROSSRAMP keys one at a time. Verify that
the lift calibration number increments or decrements as each of the CROSSRAMP keys are
pressed.