Precor EFX546 Manuel de service Page 68

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 67
C546 Elliptical Fitness Crosstrainer
Page 68
6. Two cables are in the main frame tube. The lift motor cable and the interconnect cable(s).
Locate the interconnect cable connectors in the access hole and disconnect the
interconnect cables.
7. Tape the end of the replacement interconnect cable with the small (16 pin) connector to the
upper end of the old interconnect cable (display housing end).
8. Carefully pull the old interconnect cable out of the bottom access hole while feeding the new
interconnect cable into the unit. When the new cable is fully into the unit, remove the tape
and discard the old interconnect cable. Connect the two interconnect cables and push them
into the access hole.
9. Replace the display housing per Procedure 7.2, steps 14 to 18.
10. Remove the ground lead of the wrist strap from the EFX frame, then remove the wrist strap
from your arm.
11. Check the operation of the EFX as described in Section Four.
Replacing the Lower Interconnect Cable
12. Remove the rear cover. Remove the shield from the lower PCA. Disconnect the
interconnect cable from the lower PCA. (See Diagram 7.6)
13. Lay the EFX on it’s side. The upper and lower interconnect cables are connected in the
main frame tube. Locate the access hole in the main frame tube. (See Diagram 7.8).
14. Two cables are in the main frame tube. The lift motor cable and the interconnect cable(s).
Locate the interconnect cable connectors in the access hole and disconnect the
interconnect cables.
15. Connect the male connector of the replacement interconnect cable to the old interconnect
cable at the lower PCA end of the old interconnect cable.
16. Carefully pull the old interconnect cable out of the bottom access hole while feeding the new
interconnect cable into the unit. When the new cable is fully into the unit, remove the tape
and discard the old interconnect cable. Connect the two interconnect cables and push them
into the access hole.
17. Connect the new interconnect cable to the lower PCA.
18. Replace the shield on the lower PCA. Replace the rear cover.
19. Check the operation of the EFX as described in Section Four.
Vue de la page 67