Precor EFX546 Manuel de service Page 107

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 106
C546 Elliptical Fitness Crosstrainerl
Page 107
Procedure 7.29 - Replacing a Power Entry Module
(version 2,3 units manufactured after 10-15-2000)
Procedure
Note: The power entry module on this EFX is a multifunction unit. It functions as a power entry
module, A.C. line fuse holder, on/off switch and A.C.ine filter.
1. Set the on/off switch in the off position. Remove the A.C. line cord from the A.C. outlet and
from the power entry module.
2. Remove the rear cover per Procedure 7.1.
Diagram 7.27 - Power Entry Module
3. Remove the blue wire from terminal D and the brown wire from terminal A of the power entry
module.
4. Remove the two screws that mount the power entry module to the rear cover support.
5. Open the fuse compartment and remove both fuses (See Procedure 7.30). Check both
fuses with an ohmmeter. They should read approximately 1 or less. Replace any fuse that
reads significantly high.
6. Install the tested fuses, from step 5, in the replacement power entry module.
Blue Wire
Brown Wire
Green Wire
Fuse
Access Door
On/Off
Switch
A.C. Input
Vue de la page 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 117 118

Commentaires sur ces manuels

Pas de commentaire