17. Set the on/off switch in the “on” position. Repeat step 15. If the reading is still significantly
low, replace the lower PCA. If the reading is now good, the problem is either the
interconnect cable or the upper PCA.
18. Substitute a known good upper PCA. If the upper PCA does not correct the problem,
troubleshoot the upper and lower interconnect cables per Procedure 6.1
19. If you have performed all of the above tests and are unable to resolve the problem, contact
Precor customer support.